XDS-1000

AccuMAX™ Dual Sensor Detector

السعر بعد الخصم£570.62
Brochure User manual

The AccuMAX Dual Sensor Detector (ASTM) XDS-1000 is compatible with the XR-1000 AccuMAX Radiometer/Photometer Readout Unit and has a larger aperture size (known as a cap) compared to the XDS-1000A model.

Dual UV-A/Visible Sensor Detector (XDS-1000) features:
Irradiance Range 
• UV-A Sensor 0–100 mW/cm2
• Visible Sensor 0–5,300 lux (0-500 fc)

UV-A Sensor: 365 nm

Visible Sensor: 555 nm

Dimensions
Readout Unit
Length 7.75 in (19.7 cm)
Width 4.25 in (10.8 cm)
Thickness 1.25 in (3.2 cm)
Weight 0.8 lb (360 g)

Sensor Detector 
Length 4.75 in (12.1 cm)
Width 2.0 in (5.1 cm)
Thickness 7/8 in (2.2 cm)
Weight 0.22 lb (100 g)
USB Cable 5 ft (1.5 m)

Power Requirements: Battery Operation Two non-rechargeable 9V alkaline battery cells are included as standard

Required Readout Unit (required for operation and Factory calibration)

These sensors require the following readout unit to function and cannot be calibrated without it:

  • XR-1000

 

Don't have an XR-1000? Sensors can be ordered together with a new XR-1000 for a factory-calibrated
system, or an existing XR-1000 can be returned to Spectro-UV for combined calibration, subject to applicable service fees. Contact
sales@spectro-uv.com for more details.

ASTM E2297 Compliant

Features of the XDS-1000:

  • Dual-wavelength sensor detector (measures both UV-A and visible light)
  • Sealed with water-resistant housing
  • Superior bandpass interference filter
  • Choice of direct or USB connection to readout unit
  • Excellent cosine response
  • Compact dimensions: 4.75 in × 2.0 in × 7/8 in (12.1 cm × 5.1 cm × 2.2 cm)
  • Lightweight: 0.22 lb (100 g)
  • Measurement ranges: UV-A Sensor: 0–100 mW/cm² / Visible Sensor: 0–5,300 lux (0-500 fc)

Benefits:

  • Versatility: Measures both UV-A and visible light with a single device
  • Durability: Water-resistant housing protects against environmental factors
  • Accuracy: Better than ±5% with reference to NIST standards
  • Compliance: Meets ASTM specifications for MPI and FPI (magnetic particle inspection and fluorescent penetrant inspection)
  • Portability: Lightweight and compact design for easy transport and field use
  • Flexibility: Multiple connection options for different usage scenarios
  • Precision: High-quality bandpass interference filter for accurate readings
  • Reliability: Engineered specifically for NDT (non-destructive testing) applications

Dual Sensor only

Disclaimer: Sensors purchased as standalone items are supplied uncalibrated and performance specifications are not guaranteed until calibration is completed. To receive a factory-calibrated,
specification-verified unit, sensors must be ordered together with a new XR-1000 readout unit. Customers with an existing XR-1000 may return it alongside the new sensor to Spectro-UV for combined sensor-and-unit calibration, subject to applicable service fees.

Dual UV-A/Visible Sensor Detector (XDS-1000) features:

Irradiance Range 
• UV-A Sensor 0–100 mW/cm2
• Visible Sensor 0–5,300 lux (0-500 fc)

Disclaimer: Sensors purchased as standalone items are supplied uncalibrated and performance specifications are not guaranteed until calibration is completed. To receive a factory-calibrated, specification-verified unit, sensors must be ordered together with a new XR-1000 readout unit. Customers with an existing XR-1000 may return it alongside the new sensor to Spectro-UV for combined sensor-and-unit calibration, subject to applicable service fees.

Made in USA

P/N: XDS-1000

P/N